Gemini Getfiles
1. Identify and download calibration data (biases and flux standard) from
Gemini Science Archive. (GSA Complete Catalog Query)
http://www2.cadc-ccda.hia-iha.nrc-cnrc.gc.ca/gsa/
- PI DATA PACKAGE RETRIEVAL to get science data, flats, procecessed bias, and logs. - COMPLETE CATALOG: BIASES for flux std and DARKS for targets
to DOWNLOAD DATA
- save html file as file.html
- use wget to retrieve
wget --http-user=<user> --http-password=<pswd> -B http://www1.cadc-ccda.hia-iha.nrc-cnrc.gc.ca
-F -i file1.html
to PRINT LOGS a2ps -1r -f7 -b
For calibration data
- BIASES
NEW: archive provides already processed BIAS
OLD:
Find appropriate biases with same parameters as science data
CCDSEC == [1:2048,1:4608]
CCDSUM = 2 2
- download all biases in date range of science data
- FLUX CALIBRATOR
- find biases (need to have same binning and CCDSEC as flux obs)
CCDSUM = 2 2
CCDSEC == [1:2048,1792:2815]
- DARKS (For Nod and Shuffle data)
- darks should match dark time and nodcount for objects
NODCOUNT = 8
NODPIX = 1536
EXPTIME = 900..1000
CCDSUM = 2 2
2. Once everything is downloaded, move image frames to images/ - mkdir images/
hselect > images.lis
images = "*.fits[0]"
fields = "$I"
expr = grating ?= 'MIRROR' && obstype != 'BIAS'
- emacs images.lis to get of [0] (Cntl-x r k to use a rectangular kill)
- imrename @images.lis images/
4. Make lists with different data types - OBJECTS
hselect > objects.lis
images = "*.fits[0]"
fields = "$I"
expr = obstype ?= 'OBJECT'
- FLATS
hselect > flats.lis
images = "*.fits[0]"
fields = "$I"
expr = obstype ?= 'FLAT'
- ARCS
hselect > arcs.lis
images = "*.fits[0]"
fields = "$I"
expr = obstype ?= 'ARC'
- BIASES (if one was not already processed for you)
hselect > bias.lis
images = "*.fits[0]"
fields = "$I"
expr = obstype ?= 'BIAS' && nccds = 3
- BIASES (for Nod and Shuffle data)
hselect > dark.lis
images = "*.fits[0]"
fields = "$I"
expr = obstype ?= 'DARK'
NOTE: don't forget to emacs *.lis to get rid of [0] (Cntl-X R K)
5. GPREPARE the data
- OBJECTS
inimages = @objects.lis rawpath = /data/hillary/4/kelle/optical_spectra_raw/Geminispec/GN_2004B_Q_10_2/RAW outpref = /data/hillary/2/kelle/optical_spectra/runs/gemini/GN_2004B/run2/gt fl_vard = no fl_addm = yes (Should get no warnings or errors)
- FLATS
inimages = @flats.lis rawpath = /data/hillary/4/kelle/optical_spectra_raw/Geminispec/GN_2004B_Q_10_2/RAW outpref = /data/hillary/2/kelle/optical_spectra/runs/gemini/GN_2004B/run2/gf fl_vard = no fl_addm = yes (Should get no warnings or errors)
- ARCS
inimages = @arcs.lis rawpath = /data/hillary/4/kelle/optical_spectra_raw/Geminispec/GN_2004B_Q_10_2/RAW outpref = /data/hillary/2/kelle/optical_spectra/runs/gemini/GN_2004B/run2/ga fl_vard = no fl_addm = yes (Should get no warnings or errors)
- BIASES (for flats, arcs, and not Nod & Shuffle observations)
inimages = @bais.lis outpref = /data/hillary/2/kelle/optical_spectra/runs/gemini/GN_2004B/run2/gb fl_addm = no (if set to yes, doesnt really matter, but might give error) (OK: WARNING - GPREPARE: ... use fl_addmdf=yes) (OK: WARNING - GPREPARE: ... OBSMODE=IMAGE)
- DARKS
inimages = @darks.lis rawpath = /data/hillary/4/kelle/optical_spectra_raw/Geminispec/GN_2004B_Q_10_2/RAW outpref = /data/hillary/2/kelle/optical_spectra/runs/gemini/GN_2004B/run2/gd fl_vard = no fl_addm = yes (Should get no warnings or errors)